🌏︎ EN TH KO ES RU VI
Smart Selector Get a Free Quote

Frequently Asked Questions

Everything you need to know about Meibao industrial pumps — from technology basics to ordering, shipping, and after-sales support.

7
Categories
60+
Questions
24/7
Support
FAQ & Guides
How does the cleaning method of a filter affect the service life of the filter medium?
+

Harsh cleaning (high pressure, chemical soaking, abrasive brushing) shortens filter medium life by damaging fibers, enlarging pores, or degrading binding agents. Gentle backwashing or recommended cleaning methods preserve media structure and maintain rated filtration accuracy longer.
Under the working conditions of frequent start - stops, what impacts does it have on the internal components of a magnetic pump?
+

Frequent start-stops cause thermal cycling stress on magnetic components, increased wear on bearings from repeated torque shocks, and potential demagnetization risk from rapid temperature changes. Use soft starters or VFDs to reduce mechanical stress on the magnetic coupling.
What different filtration precisions are available for filters?
+

Filtration precision options typically range from coarse (50-100 microns) for general particle removal, medium (5-25 microns) for standard process filtration, fine (1-5 microns) for precision applications, to ultra-fine (0.1-1 micron) for high-purity requirements.
What special sealing designs does a chemical pump have for transporting highly volatile media?
+

For highly volatile media: magnetic drive (zero leakage) is preferred; double mechanical seals with barrier fluid; vapor-pressure-matched seal materials; pressure-rated casing; and proper venting design to prevent vapor lock and flashing.
What are the precautions when installing a vertical pump in a narrow space?
+

In narrow spaces:
1) Verify vertical clearance for removal,
2) Ensure access to motor terminals,
3) Plan for discharge piping routing,
4) Allow minimum clearance for inspection and maintenance,
5) Consider mounting orientation and structural support requirements.
What performance changes will occur when a fan continuously operates in a high - temperature environment?
+

In high-temperature environments: fan materials expand affecting clearances, lubricant viscosity decreases potentially causing bearing failure, motor efficiency drops and risk of overheating increases, and air density changes alter fan performance. Use high-temperature rated motors and heat-resistant materials.
1 ... 13 14 15 16 17 18 19 20 21 ... 24
No matching questions found
Try a different keyword or browse all categories above.
Contact Our Engineers Instead
Didn't find the answer you were looking for?
Our engineering team responds to technical inquiries within 24 hours. You can also check our downloadable technical guides and case studies.