Home Wastewater & Exhaust Gas Treatment AAL Electroplating Pickling Case Study-123
Electroplating Pickling India Completed: November 2025

Zero-Leakage Vertical Pickling Pump:
450 L/min, 7+ Months of Continuous Operation


How an Indian electroplating facility reduced downtime and acid-related corrosion by switching to PPH vertical pumps for mixed-acid pickling circulation.

Meibao pumps provide stable corrosion resistance and rarely leak during continuous operation. Compared with other brands, they need much less maintenance and have significantly reduced production downtime.

NV
Patel
Director
AAL

From Three Major Leakage Incidents to 36 Months of Bulletproof HF Transfer

Viet Semiconductor Components JSC operates a 200mm wafer fabrication facility in Ho Chi Minh City, Vietnam, processing 12,000 litres of hydrofluoric acid daily for silicon wafer etching. A history of pump failures and toxic HF leakage incidents made this one of Meibao's most demanding  | and most rewarding  | installation projects.

01
The Challenge


Acid Fumes, Corrosion, and Repeated Pump Failures

AAL is an electroplating company in India. Its pickling process uses a 20% hydrochloric acid and sulfuric acid mixture at 60°C to remove oxide from metal surfaces.

The pickling tanks continuously circulate the acid solution through filter machines to keep the bath clean. However, the open tanks release corrosive acid fumes into the workshop. At the same time, the acid contains a large amount of iron oxide sludge, creating both chemical corrosion and particle wear inside the pump.

The Problems

Before working with Meibao, AAL had tried several pump brands, but none could provide stable operation under these conditions.

The main problems included:

  • Acid fumes                                  attacked the motor and bearings.
  • Iron oxide                                    particles caused wear on the impeller and pump casing.
  • The average                                pump service life was only about 12 months.
  • Pump failures                            caused repeated repairs and replacements.
  • Production                                 downtime reached around 15 days per year.
  • Acid leakage                              occurred 2–4 times per year, creating safety and EHS concerns.

The customer needed more than a pump with better corrosion resistance. The solution also had to address acid-fume exposure, leakage, and changing tank levels.

Root Cause

Why were the previous pumps failing?

1. Acid-fume exposure
Open pickling tanks continuously released HCl + H₂SO₄ fumes. Horizontal pumps left the motor and bearing area exposed to the corrosive environment.

2. Corrosion + particle wear
The 20% mixed acid attacked wetted components, while iron oxide sludge accelerated mechanical wear.

3. Shaft-seal leakage
The shaft seal became a weak point under corrosive conditions, leading to repeated acid leakage.

4. Tank-level changes
Changes in liquid level could make the horizontal pump more likely to lose stable suction conditions, increasing the risk of cavitation.

Before Meibao

Metric

Before Meibao

Impact

Pump Lifespan

About 1 year

Frequent replacement

Annual Downtime

15 days/year

About 2 weeks of production lost

Leakage Incidents

2–4 times/year

EHS and operator safety concerns

Annual Pump Cost

$500/set

Purchase + labor + downtime

Acid Concentration

20%

HCl + H₂SO₄ mixed acid

Operating Temperature

60°C

Increased corrosion and seal wear

02
Our Solution


A Vertical Pump with PPH Wetted Parts

After reviewing AAL's actual operating conditions, Meibao identified three key requirements:

Keep the motor away from acid fumes. Prevent shaft-seal leakage. Maintain stable operation when the tank level changes.

A conventional horizontal pump could not fully address these issues.

Meibao therefore recommended the MIT-40VK-55NF vertical pump.

Its vertical design places the motor above the liquid level, while the seal-less structure removes the traditional shaft-seal leakage point. PPH wetted parts were selected for the customer's mixed-acid application and 60°C operating temperature.

Why MIT-40VK-55NF?

Selection Requirement

MIT-40VK-55NF Advantage

Acid-fume exposure

Motor is positioned above the liquid level and away   from the main fume area

Corrosive liquid

PPH wetted parts are designed for corrosive chemical   service

Leakage prevention

Seal-less design removes the mechanical shaft-seal   leakage point

Changing liquid levels

Vertical submerged pump design helps maintain stable liquid   intake

Circulation flow

Up to 450 L/min for filter-machine circulation

Key Advantages

Vertical Design · Seal-Less Structure · Stable Operation

·         Motor away from acid fumes: The vertical design keeps the motor above the liquid level, reducing exposure to corrosive fumes.

·         No shaft-seal leakage: The seal-less design removes a common leakage point found in conventional shaft-seal pumps.

·         Better handling of changing liquid levels: The submerged pump section stays in the liquid, helping maintain stable suction as the tank level changes.

·         PPH wetted parts: The wetted components are made from PPH for corrosion resistance in the customer's mixed-acid application.


Selected Pump Specifications

Specification

MIT-40VK-55NF

Key Benefit

Wetted Material

PPH

Corrosion-resistant wetted parts

Drive Type

Vertical direct drive

Seal-less pump design

Max. Flow

450 L/min

Stable circulation to filter machines

Max. Head

21 m

Handles system back pressure

Motor Power

3.75 kW

Suitable for the application

Units Installed

6

Covers the customer's pickling system

Sealing

Seal-less

No mechanical shaft seal

Certification

None required

Standard industrial application


Project Timeline

Stage

Timeline

What Happened

Application Review

Week 1–2

Reviewed the pickling process, liquid-level changes,   and piping layout

Production & Testing

Week 3–5

Six MIT-40VK-55NF pumps were customized to match the   customer's connections and fully inspected before shipment

Installation & Commissioning

Week 6–7

Pumps were installed, connected, tested, and   commissioned under load

Stable Operation

Month 7+

Pumps have continued running without failure and are   still being monitored


03

The Result

Zero Leakage and Stable Operation for 7+ Months

Since installation and commissioning were completed in November 2025, all six MIT-40VK-55NF vertical pumps have operated continuously for more than 7 months in AAL's pickling workshop.

During this period:

  • 0 leakage      incidents
  • 0 days of      production downtime caused by the pumps
  • Stable      circulation of up to 450 L/min
  • No pump      failures requiring replacement
  • Significantly      less maintenance compared with the previous pumps

The vertical design also keeps the motor above the liquid level, reducing its exposure to the acid-fume environment.

At the same time, the seal-less design removes the shaft-seal leakage point, helping keep the working area cleaner and reducing EHS concerns related to acid leakage.

Customer Feedback

“Meibao pumps provide stable corrosion resistance and rarely leak during continuous operation. Compared with other brands, they need much less maintenance and have significantly reduced production downtime.”

Patel, Director, AAL

Before vs. After

Area

Before: Horizontal Pumps

After: MIT-40VK-55NF

Result

Corrosion

Wetted parts required replacement after about 12 months

PPH wetted parts have operated for 7+ months with no   reported corrosion-related failure

Longer expected service life

Acid Leakage

2–4 incidents/year

0 incidents

Leakage eliminated during the reported period

Production Downtime

15 days/year

0 days caused   by pump failure during the reported period

Production interruptions reduced

EHS Risk

Repeated acid leakage created safety and environmental   concerns

No reported leakage since installation

Lower leakage-related risk

Annual Pump Cost

About $500/set

About $200/set equivalent based on reported annual   saving

About $300/year saving

Note: The reported 7+ month operating period confirms the current performance of the installed pumps. Longer-term service-life improvements will be evaluated as operation continues.



Products Deployed in This Project

IT-40VK-55NF Vertical Pump

Specification

Details

Flow

450 L/min

Head

21 m

Wetted Material

PPH

Motor Power

3.75 kW

Drive

Vertical direct drive

Temperature Rating

80°C

Quantity

6 Units

Configuration: Standard configuration. No additional spare parts package was supplied.

Get a Free Technical Proposal

Tell us about your HF acid, chemical, or corrosive media application. Our engineering team will recommend the right pump and provide a detailed proposal within 48 hours.