Electroplating Pickling & Surface Finishing India Completed: April 2026

Vertical Pumps for Electroplating Pickling & Surface Finishing

Zero-Leakage Vertical Pumps for Mixed-Acid Pickling: 5,800 L/h Circulation, 7+ Months Uninterrupted

Meibao pumps deliver stable corrosion resistance and rarely leak during continuous operation. The vertical structure keeps the motor above the liquid surface, helping protect it from acid fumes. Unlike horizontal pumps, they are less likely to draw in air when the liquid level changes. The after-sales service is also very good.

NV
Ambarish, Managing Director

Case Study: Vertical Pumps for Electroplating Pickling & Surface Finishing

How an Indian electroplating facility reduced downtime, acid-fume corrosion, and leakage across pickling, anodising, and zinc-nickel plating lines by switching to FRPP vertical pump

01
The Challenge

Multiple Process Lines, Multiple Chemicals, and Heavy Acid Fumes

The customer is an electroplating company in India with several surface-treatment processes, including pickling, anodising, and zinc-nickel plating.

Different process lines use hydrochloric acid, mixed hydrochloric/sulfuric acid, and other plating solutions. Operating temperatures can reach 60–65°C. At the same time, the open pickling tanks continuously release corrosive acid fumes, creating a highly corrosive environment throughout the workshop.

The production system had 11 tank positions that required continuous liquid circulation to filter machines. The pumps therefore had to operate reliably under demanding chemical, temperature, and installation conditions.



The Main Problems

Before switching to Meibao, the customer had tried several pump brands, but the pumps could not provide stable long-term operation in this environment.

1. Acid-Fume Corrosion

The workshop contained high levels of corrosive HCl + H₂SO₄ fumes. On conventional horizontal pumps, the motor and bearing areas were exposed to the fumes for long periods, leading to frequent electrical and mechanical problems.

2. Chemical Corrosion and Particle Wear

Iron oxide sludge in the acid solution, together with the chemicals used in the plating processes, attacked the wetted parts and increased wear.

3. Repeated Leakage

The shaft seal was a weak point in the previous horizontal-pump setup. Exposure to corrosive fumes and liquid could damage the seal, resulting in 2–4 acid leakage incidents per year.

4. Changing Liquid Levels

Changes in tank level could cause horizontal pumps to draw in air, increasing the risk of unstable operation and cavitation.

As a result, the average pump service life was only about 12 months. Pump failures required maintenance or replacement and caused around 15 days of production downtime per year.






Root Cause

Why were the previous pumps failing?

1. Multiple corrosive media
The production lines handled pickling acids, anodising solutions, and zinc-nickel plating solutions. The pumps needed to handle several demanding chemical environments.

2. Acid-fume exposure
Open tanks continuously released HCl + H₂SO₄ fumes, exposing horizontal-pump motors and bearings to a corrosive environment.

3. Shaft-seal problems
The shaft seal was a major potential leakage point under corrosive operating conditions.

4. Solid particles in the liquid
Iron oxide sludge increased wear and could further affect sealing components.






Before Meibao

Metric

Before Meibao

Impact

Pump Lifespan

About 1 year

Replacement required across 11 stations

Annual Downtime

15 days/year

Significant production time lost

Leakage Incidents

2–4 times/year

EHS and operator safety concerns

Annual Equipment Cost

$500/set

Purchase + labor + downtime

Medium Concentration

20%

Mixed HCl + H₂SO₄

Operating Temperature

60–65°C

Increased corrosion and seal wear

Process Lines

Pickling / Anodising / Zn-Ni Plating

Multiple corrosive media


02
Our Solution

One Vertical Pump Solution for 11 Process Stations

After reviewing the customer's operating conditions, Meibao found that the problem was not simply about replacing one pump with another.

The customer needed a solution that could support pickling, anodising, and zinc-nickel plating, handle different corrosive liquids, reduce exposure to acid fumes, and address the leakage problems associated with shaft seals.

For this reason, Meibao recommended the MFL Series vertical pump and replaced the existing pumps at all 11 tank positions.



Why the MFL-206-MNX-F-1?

  • Vertical      design: Keeps the motor above      the liquid level and away from the main acid-fume area.
  • FRPP wetted      parts: Fiber-reinforced      polypropylene provides corrosion resistance for the customer's chemical      applications.
  • Seal-less      design: Removes the mechanical      shaft seal as a common leakage point.
  • One pump      model across the lines: Simplifies      operation and spare-parts management.






Product Selection

Selection Requirement

MFL-206-MNX-F-1 Advantage

Vertical installation

Motor is positioned above the liquid level and away   from the main fume area

FRPP wetted parts

Fiber-reinforced polypropylene for the customer's   pickling, anodising, and zinc-nickel applications

Seal-less design

Removes the mechanical shaft-seal leakage point

Changing liquid levels

Submerged pump design helps maintain stable liquid   intake

Stable circulation

5,800 L/h circulation for the filter machines

One standard model

11 identical pumps simplify operation and spare-parts   management






Key Technical Advantages

Vertical Design · Seal-Less Structure · One Solution Across the Lines

·         Motor away from acid fumes: The vertical design keeps the motor above the liquid level, reducing exposure to corrosive fumes.

·         No mechanical shaft seal: The seal-less design removes a common leakage point.

·         Stable operation with changing liquid levels: The submerged pump section remains in the liquid, helping maintain stable liquid intake.

·         FRPP wetted parts: Fiber-reinforced polypropylene combines corrosion resistance with good mechanical strength for demanding chemical service.

·         One model for all 11 stations: Using the same pump model across the process lines makes operation and maintenance simpler.






Selected Pump Specifications

Specification

MFL-206-MNX-F-1

Key Benefit

Wetted Material

FRPP (Fiber-Reinforced Polypropylene)

Corrosion-resistant for mixed acid, anodising, and   zinc-nickel solutions

Drive Type

Vertical direct drive

Seal-less pump design

Max. Flow

5,800 L/h

Stable circulation to filter machines

Max. Head

14 m

Handles system back pressure

Motor Rating

1 HP (750 W)

Suitable power for the application

Units Installed

11 units

Covers all process lines

Sealing

Seal-less, vertical submerged design

Removes the mechanical shaft seal

Certification

None required

Standard industrial application






Project Timeline

Stage

Timeline

Details

Application Review

Week 1–2

Reviewed the three process lines, operating conditions,   and piping layout

Production & Testing

Week 3–5

11 MFL-206-MNX-F-1 pumps customized to the customer's   connections and inspected before shipment

Installation & Commissioning

Week 6–7

Installed all 11 pumps, connected the piping, and   completed commissioning and load testing

Stable Operation

Month 7+

Continuous operation without reported pump failure;   performance continues to be monitored


03
The Result

Zero Leakage, Zero Pump-Related Downtime, and $1,000 in Annual Savings

Since the pumps were commissioned in April 2026, all 11 MFL-206-MNX-F-1 vertical pumps have operated across the customer's three surface-treatment process lines.

During the reported operating period, the pump system has achieved:

  • 7+ months of      continuous operation
  • 0 reported      leakage incidents
  • 0      pump-related production downtime
  • Stable      circulation of up to 5,800 L/h
  • Lower      maintenance requirements compared with the previous pumps
  • Approximately      $1,000 in annual equipment-related savings


The vertical design keeps the motor above the liquid surface, helping reduce exposure to acid fumes. The seal-less design also removes the mechanical shaft seal as a common leakage point.


Ambarish, the Managing Director, also highlighted Meibao's after-sales service as an important part of the overall experience.


Customer Feedback

“Meibao pumps deliver stable corrosion resistance and rarely leak during continuous operation. The vertical structure keeps the motor above the liquid surface, helping protect it from acid fumes. Unlike horizontal pumps, they are less likely to draw in air when the liquid level changes. The after-sales service is also very good.”

— Ambarish, Managing Director


Recommended Pumps for
Vertical Pumps for Electroplating Pickling & Surface Finishing

Each pump model is available in multiple material configurations to match the exact chemical and thermal requirements of your process.

Stainless Steel Vertical Pump Recommended
Stainless Steel Vertical Pump
96 m³/h Max Flow 39 m Max Head 0.37-11.19kW Power -Max Temp -Max Pressure -Warranty
View Details
Out-of-Tank Vertical Chemical Pump Recommended
Out-of-Tank Vertical Chemical Pump
110 m³/h Max Flow 36 m Max Head 0.75-22.371kW Power -Max Temp -Max Pressure -Warranty
View Details
Vortex chemical centrifugal pump Recommended
Vortex chemical centrifugal pump
230 m³/h Max Flow 48m Max Head 11-22kW Power 90 °CMax Temp 4.8 kgMax Pressure -Warranty
View Details
Vortex Perfluorinated Centrifugal Pump Recommended
Vortex Perfluorinated Centrifugal Pump
230 m³/h Max Flow 48m Max Head 11-22.37kW Power 90 °CMax Temp 4.8 kgMax Pressure -Warranty
View Details
View All Products

Get a Free Technical Proposal